Shuttle Premium

Soundproofing Weatherproof Heat Insulating Heat-Resistant Latex
Liquid water-based extra-latex coating on polymer microspheres up to 40 microns in size, resistant to atmospheric and other influences. Provides various surfaces with unique thermal insulation, hydrophobic and light (heat) reflective properties. The coating SHUTTLE PREMIUM is capable of reducing heat loss on various materials up to 50% and has no direct analogues among similar systems, being the most innovative product on the market of liquid thermal insulation.
Liquid latex aqueous emulsion coating on purified ceramic microspheres up to 80 microns in size. Possesses heat-insulating, hydrophobic and reflecting properties. Creates a durable weather-resistant coating of light gray, resembling facade or interior paint. Provides reduction of heat losses on various surfaces up to 30%. Has heat resistance up to 250 оС.
Liquid water-based heat-resistant coating on microspheres and crystals, having a complex chemical composition. It is used mainly on materials heated to high temperatures, more than 200 оС. It has a dark gray, almost black color. Provides adequate thermal insulation to hot metal surfaces. Temperature resistant up to 500 оС.
Premium Standard Thermo
Colour:
Light gray, with the possibility of tinting
Heat resistance:
260°
Liters
1l./3l./10l.
Colour:
Dark gray
Heat resistance:
200-400°
Liters
1l./3l./10l.
Colour:
Colour white, with accurate tinting system according to RAL and cis.
Heat resistance:
150°
Liters
1l./3l./10l.
Colour:
Light gray, with the possibility of tinting
Heat resistance:
150°
Liters
1l./3l./10l.
200 uah.
Buy

Coating properties

Thermal insulation
Provides reduction of heat losses on various surfaces up to 50%. It can serve as additional and main insulation.
Thermal insulation
Provides reduction of heat losses on various surfaces up to 30%. It can serve as additional and main insulation.
Thermal insulation
Provides reduction of heat losses on various surfaces up to 30%. It is used as a thermal barrier for high-temperature metal surfaces, chimneys, exhaust systems and industrial equipment with high temperatures from +200 to +500 C. It has a unique heat resistance and the ability of double thermal reflection from the surface of crystals and microspheres.
Heat mirror
Heat mirror It reflects heat radiation. In summer, up to 95% of solar radiation reflected in the outdoors, in winter up to 50% of the thermal radiation reflected inside the room.
Soundproofing
Reduces noise in an isolated room.
Hydrophoby
1.8% water absorption, surface absorption coefficient (kg / m2h) that is not more than 0,001 It is moisture and thus is not a vapor barrier ("breathing" wall). It creates the effect of drying the walls, in which the "dew point" is always to be on the outer surface.
Anticorrosi
It prevents corrosion of the metal, since it does not transmit moisture.
Anti-fungal coating
It does not allow the development of mildew and destroys existing mycelium.
The durability of the coating
Manufacturer's warranty of 10 years!
Ease of work
Application by brush, roller, spatula, spray
Adhesion
Adhesion to almost all construction materials and structures.
Use as a finish
Use as a topcoat with tinting according to the RAL system.

Applications

Industrial and Civil Engineering
Walls, foundation, basement, floors, roofs of residential and industrial buildings and structures; Warming and gidrobarer joints in prefabricated buildings; Metal sheds, garages, warehouses, crane girders; Bridges, tunnels (ensures waterproofing, significantly reduces freezing and corrosion);
Boiler equipment and ventilation systems. Pipelines
КBoilers, pipes and water heating systems, valves, (prevention of heat in the summer, the absence of condensation in the dew point); Gas pipes, steam pipes, heat exchangers; Air ducts, ventilation systems.
Chemical and petrochemical industry
Oil pipelines, gas pipelines; Tanks, storage tanks and transportation of petroleum products, quick-flammable liquids, chemicals (decrease heating, evaporation, increasing the filling).
Transport and Shipbuilding
Coverage of bodies, heads of vehicles, refrigerated trucks, tanks, containers, w / d cars, buildings sea and river vessels, boats.
Food industry and agriculture
Stationary cold storage and mixing tanks; Farm animals; Elevators.

Specifications

Thermal conductivity (W / m ° K), at least
0.002
The heat transfer coefficient of the outer surface (W / m2 ° K)
1.5
Drying time at 20 ° C, an hour at least
12
Operating temperature range, °С
- 60° +150°
Tensile strength, kg / cm2
9
Elongation at break,%, not less
1.2
Viscosity, g/cm3
0.7-1.5
Mass fraction of solids, %
40-70
Water absorption of coatings for 24 hours,% by weight
up to 15
Water vapor permeability coating mg/(m*year*Pa), not more
0.02
Frost, zamorazhivanie- thawing at temperatures -60°С +240°С
300 cycles
Adhesion, MPa, no less:

- to metal (steel)

- to concrete

- to wood


0.6

0.8

1.0

Thermal conductivity (W / m ° K), at least
0.01
The heat transfer coefficient of the outer surface (W / m2 ° K)
1.0
Drying time at 20 ° C, an hour at least
12
Operating temperature range, °С
- 60° +260°
Tensile strength, kg / cm2
9
Elongation at break,%, not less
1.2
Viscosity, g/cm3
0.7-1.5
Mass fraction of solids, %
40-70
Water absorption of coatings for 24 hours,% by weight
up to 15
Water vapor permeability coating mg/(m*year*Pa), not more
0.02
Frost, zamorazhivanie- thawing at temperatures -60°С +250°С
300 cycles
Adhesion, MPa, no less:

- to metal (steel)

- to concrete

- to wood


0.6

0.8

1.0

Thermal conductivity (W / m ° K), at least
0.01
The heat transfer coefficient of the outer surface (W / m2 ° K)
1.0
Drying time at 20 ° C, an hour at least
12
Operating temperature range, °С
- 60° +500°
Tensile strength, kg / cm2
9
Elongation at break,%, not less
1.2
Viscosity, g/cm3
0.7-1.5
Mass fraction of solids, %
40-70
Water absorption of coatings for 24 hours,% by weight
up to 15
Water vapor permeability coating mg/(m*year*Pa), not more
0.02
Frost, zamorazhivanie- thawing at temperatures -60°С +500°С
300 cycles
Adhesion, MPa, no less:

- to metal (steel)

- to concrete

- to wood


0.6

0.8

1.0

Comparison table of thermal conductivity performance:
Material
Coefficient of thermal conductivity
Thickness
Silicate brick
0,8
35 cm
20 cm
20 cm
Clay brick
0,5
25 cm
14 cm
14 cm
Foam (or laminated wooden beams)
0,2
15 cm
8 cm
8 cm
Mineral wool (basalt)
0,05
5 cm
2,5 cm
2,5 cm
Expanded polystyrene PSB-25
0,03
3 cm
1,5 cm
1,5 cm
SHUTTLE PREMIUM
SHUTTLE STANDARD
SHUTTLE THERMO
0,0025
0,009
0,009
2 mm

Application Instructions

Technological instructions for applying liquid composite insulation coating "SHUTTLE" on concrete, brick, plaster, metal and other surfaces
Coating
Before applying to the surface, "SHUTTLE" mixed until smooth. Stirring means done by hand, mechanically or by means of a mixer (an electric drill with paddle). Peremeschivanie should be implemented at low speed, for 3-5 minutes until smooth. If necessary, the viscosity reducing agent is diluted with water. Add water to be consistent, in small portions, 1% by weight of dye (but not more than 5.7% of the total weight of the agent). "SHUTTLE" can be applied by airless spray high-pressure units with a nozzle diameter of at least 2 mm, roller or brush. It is recommended to use "CEILING" brush (wide flat brush with dense bristles). The coating should be applied to cross-layers (one along the other transverse or vice versa). The drying each layer - at least 20 minutes at a temperature (20 ± 2) ° C. Duration interlayer drying at other temperatures determined on the curing degree. When you touch on the cover should not be a trace. Apply the product must be at ambient temperature not lower than 5 ° C and relative humidity above 80%. To achieve the "Shuttle" covering essential characteristics recommend to apply the coating layer in an amount of not less than 3!
Metal surfaces
In the preparation of metal surfaces, be painted, should be guided by the requirements of SNIP 3.04.03 and GOST 9.402. Metal surfaces should be thoroughly cleaned and primed, it is desirable that a special primer for rust. In the case of application to the stainless surface treat 10% caustic solution (100 g per 1 liter of soda water). On the metal surface becomes hot recommended application from 7 to 10 layers to the overall coating layer was in the range of 1.5-3 mm for better thermal insulation. At the same generic fiber polymerization occurs within two days after application and only then you can start heating surfaces. Over time, the surface color can darken or change due to thermal effects of high temperatures on the latex that does not affect the coating characteristics.
Concrete. Brick. Plaster. A rock.
Before applying the funds to concrete, brick, stone, plaster surfaces, they must be free from all kinds of dirt, dried and filled, for example ST17 primed or her peers. 4-5 applied in layers, depending on the requirements of the object. It is not allowed the presence of moisture or condensation on surfaces to be painted.
Quality control work
Quality control works on application of insulating coatings on concrete, brick, plastered surfaces is carried out at each operation. Subject to the quality control of surface preparation prior to coating as well as coating quality and thickness of insulating coatings. The quality of surface preparation prior to application of funds is checked visually by a check for dirt and lack not primed areas. Acceptance of the prepared surface to draw up an act of covert work. Quality insulating coating after drying is controlled visually. In this case check: no cracks, no blistering, delamination and fraying, no unprotected areas of surfaces.